Now recruiting capture teams worldwide. Get paid to record first-person video of real work.

Apply to capture

Task family

Stereo Lab Pipetting and Sample Handling Data

Draw liquid into a pipette, dispense it into a tube, change the tip, cap, rack and label: bench work is small vessels, two hands and a written order of steps, and the pipette, the tube and the fingers hide a lot from a single camera. This page covers the stereo and container side of lab automation robot training data for the catalog rows that name this work: what a calibrated stereo pair adds to stereo pipetting video, what MCAP is according to its own documentation, and what the site does not state. We run egocentric liquid handling dataset collection fast and on demand against a spec you write, as custom laboratory data collection at scale through a network of thousands of capture providers, for a consistent, recurring data flow to labs.
Catalog rows
Pipetting, Liquid handling and Lab protocols (Pharmacy & Laboratory), plus four sample-tube rows (Wet Lab & Clinical Bench)
Status
All Available on request
Container
MCAP (.mcap), open source
License
Perpetual, buyer-owned

Why stereo and MCAP here

What do a stereo pair and an MCAP file add to lab pipetting video?

01

Depth for small vessels and tools

The site states that a stereo pair at human-eye spacing makes depth recoverable from every frame pair, so the pipette, the tip, the tube and the hands sit in one frame. The site gives no depth accuracy figure for these rows and does not state how depth behaves on small, shiny or transparent items.

02

Fingers hidden by the pipette, flagged not guessed

The site states that fingers disappear behind objects and that the hands occlude the work. 3D hand pose carries a per-joint visibility flag, so a finger hidden behind a pipette body or a tube is marked as hidden rather than silently filled in.

03

Draw, dispense and change tip as separate steps

The rows name drawing liquid into the pipette, dispensing into tubes, changing tips, filling, capping, vortexing, racking and labeling. Action segments carry start_ns, end_ns, verb and noun, so each step can be its own labeled span. Which verbs and nouns are used is set in the skill spec.

04

Several streams in one container

MCAP stores multiple channels of timestamped, pre-serialized data, so a stereo pair, hand pose and IMU can share one file on one log-time axis. Which streams go in the file is set in the skill spec.

Definition

What is stereo lab pipetting and sample handling data?

It is first-person video of a person doing bench work, recorded with two calibrated cameras, with hand pose and sensor streams alongside. People reach it through several phrasings: lab automation robot training data, stereo pipetting video, egocentric liquid handling dataset, or custom laboratory data collection at scale. They describe one request from different angles. Stereo describes the capture, and MCAP describes the container. They are separate choices.

The site does not state that stereo is already running on these rows. The catalog lists a head-mounted phone or a multiview rig as the capture setup for the Pharmacy & Laboratory rows, so a stereo pair is a capture choice agreed in the skill spec and confirmed on a Spec Pilot. The data is human capture by paid, consented contributors, not robot or teleoperation data, so using it for a specific robot still needs your own retargeting step. Firsthand is not affiliated with Foxglove or the MCAP maintainers.

Catalog rows

Which catalog rows does this page rely on, and what is their status?

Seven, listed in lib/commercial-catalog-data.ts. Three sit in Pharmacy & Laboratory, in the Healthcare & Life Sciences sector: "Pipetting" and "Liquid handling", both rated Medium, and "Lab protocols (pipetting, titration, sample handling)", rated Hard. Four sit in Wet Lab & Clinical Bench and cover sample tubes: "Fill + cap sample tubes", "Cap, vortex + rack tubes" and "Load + balance centrifuge", rated Medium, and "Rack + label tubes", rated Easy. All seven are listed as Available on request.

The site defines Available on request as work that a spec starts, rather than a running capture stream a spec can join. That is a statement about the catalog row, not a promise of a delivery date. The site states no delivered hours and no delivered stereo footage for any of these rows, so this page claims none. Other lab rows, such as "Laboratory Work", "Weigh reagent", "Prepare a slide", "Swab + streak plate" and "Titrate to endpoint", are real catalog rows but are outside this page. The first table below reproduces the seven rows as the catalog states them.

Difference

How is this different from the egocentric lab pipetting page and the medication sorting page?

This page is the stereo and MCAP treatment of lab pipetting, liquid handling and sample handling. The egocentric lab pipetting and sample handling page covers fourteen catalog rows, five from Pharmacy & Laboratory and nine from Wet Lab & Clinical Bench, as first-person video, and stereo is not its subject. It is the non-stereo page for the same bench work, and it also reproduces rows this page leaves out, such as weighing a reagent and titrating to an endpoint.

The egocentric medication sorting and dispensing page covers three medication rows across Care Room, Nursing Home & Assisted Living and Pharmacy & Laboratory, all Available on request. That is pharmacy work with blister packs, charts and prescriptions, not liquid transfer at a bench. The second table below sets the pages side by side with each status as the site lists it.

Capture setup

What capture setup do the rows list, and where does stereo come in?

The catalog lists "Phone (head-mounted) / multiview rig" for the three Pharmacy & Laboratory rows and "Multiview rig + handheld grippers" for the four sample-tube rows. The site does not state a stereo pair for any of them. Stereo applies through the site’s general stereo offer: a stereo pair is a capture choice agreed in the skill spec and confirmed on a Spec Pilot. The site also states that Firsthand does not capture at a customer’s own facility, so the setting is agreed in the spec.

The site describes two stereo setups and does not say which one an order for these rows uses. The hard-environments stack is a global-shutter 4K/60 head camera with a 120° lens, two 1080p/60 wrist cameras, a depth sensor at 848×480 and 30 fps, and 200 Hz 6-DoF IMUs. The off-the-shelf stereo head rig, dataset 06, is dual fisheye cameras at 1080p per eye, a 62 mm baseline, per-unit calibration, a 9-axis IMU and hand-tracking output. For the sample-tube rows, the handheld grippers named in the catalog are part of the stated setup; whether a stereo pair is worn, mounted or combined with them is Not stated.

Why stereo

Why capture pipetting and sample handling in stereo?

Bench work is about where a tip meets a tube: how the pipette is held, where the plunger sits under the thumb, how a tube is steadied while it is filled or capped. A stereo pair recovers depth from the calibrated frame pair rather than from a standalone depth sensor, so the geometry sits in the same capture that shows the hands working. The site gives no depth accuracy figure for these rows, so what a buyer does with that depth is their pipeline’s question.

A stereo pair adds depth, not a verdict. The site lists no volume, liquid level, sample identity or result label for these rows, and none is claimed. The egocentric lab pipetting page already supplies the first-person framing; stereo is the addition for a buyer who wants the depth and the MCAP file.

Steps

Which steps of pipetting and sample handling can a stereo spec label?

The rows give a natural cut. The pipetting row draws liquid into the pipette, dispenses exact volumes into tubes and changes tips. The liquid handling row measures and transfers liquids between vessels with pipettes, cylinders and dispensers. The tube rows fill to a mark, cap, vortex-mix, rack in order, label and load tubes balanced in a centrifuge. A spec that says "do the protocol" gives one long action segment. A spec that names the steps gives a sequence you can slice by step.

Whether drawing and dispensing are one segment or two, and whether capping and racking are one segment or two, is a spec decision, not a default. The site does not set an episode length, so the spec says whether one episode is one transfer, one tube, one rack or a whole protocol run. Contact events can mark when a hand meets an item, where the spec asks for them, and the spec decides what counts as the item, including whether a pipette tip or a tube cap qualifies.

Occlusion and small objects

What do the hands, the pipette and small transparent objects do to visibility?

A pipette, a thumb and a tube can all sit between the lens and the work. The site states that the hands occlude the work and that fingers disappear behind objects. That is why each hand joint carries a visibility flag, why contact events mark when the hand meets the item, and why instance masks are recorded per frame. It also states that reach and grasp frames are where blur and occlusion show up, and the head camera in the hard-environments stack is global-shutter, which avoids rolling-shutter skew.

The site does not state how depth behaves on small, shiny or transparent items, and the catalog row text does not describe the tube or vessel material. It states that depth degrades on wet and reflective surfaces, with confidence maps masking low-confidence regions. The site’s tool use page says grip changes and tool hand-off live in finger-level detail that RGB video alone cannot resolve, and that metric depth on sub-centimetre parts is flagged rather than interpolated. That page is about driving and fastening tools, not pipettes, so this page does not claim the same findings for lab work. If your policy depends on glass labware, liquid in a vessel or a transparent tube, say so in the spec and settle it on a Spec Pilot.

Surfaces and light

What does the site say about glare, lighting and bench surfaces?

The site states that glare-heavy and low-texture scenes make single-frame depth worse, and that depth degrades on wet and reflective surfaces. A benchtop, a metal rack and a glass vessel are plausible cases, but the site does not say how often they occur or how depth behaves on them. A lighting setup for the lab rows is Not stated.

Where a program needs a specific bench layout, lighting or background, that goes into the spec and is checked on a Spec Pilot. An episode is rejected when more than 35 percent of depth pixels in the manipulation region are invalid, and for this job the spec decides what the manipulation region is at each step. Equipment, consumables, assays and protocols beyond the pipettes, cylinders, dispensers, tubes, centrifuge and rows named in the catalog are Not stated.

Safety and privacy

What does the site say about lab safety, compliance and privacy?

The catalog notes that the Pharmacy & Laboratory work requires regulatory compliance, and a separate catalog row lists putting on gloves and eyewear, handling chemicals under the hood and disposing of waste correctly. This page makes no GLP, GMP, biosafety, chemical safety, sterility or certification claim of its own: all of those are Not stated. The site states no patient-data handling for these environments, and this page covers no patient-facing task.

For every delivered episode the site states that faces and screens are blurred irreversibly, that a reviewer confirms no un-consented person is identifiable, and that footage that cannot be de-identified is discarded. The anonymization record ships with the data, an undocumented bystander is a stated reject criterion, and every episode links to a signed contributor release. Tube labels, sample labels and container markings are not listed as blur categories, so this page does not claim they are blurred. If label text in frame matters, raise it in the spec. This is not legal advice, and the executed agreement controls.

MCAP

What is MCAP, per its own documentation?

MCAP is an open source container file format for multimodal log data, supporting multiple channels of timestamped pre-serialized data. It is serialization-agnostic, so messages can be Protobuf, DDS (CDR), ROS, JSON and more. Its design is row-oriented and append-only, it stores schemas alongside the data, and it offers an optional index plus optional LZ4 or Zstandard chunk compression.

Reader and writer libraries exist for C++, Go, Python, Rust, Swift and TypeScript, and the mcap CLI can inspect, merge and split files. The foxglove/mcap repository is MIT-licensed; that is the MCAP project licence, not the licence of a Firsthand delivery. The MCAP hub page and the glossary entry cover the format in full.

Streams

Which streams can ship in an MCAP delivery of lab pipetting data?

Firsthand offers MCAP delivery, and dataset 06 is stated as shipping as MCAP. For these rows the site states hand pose, a stereo-derived depth stream with confidence maps, IMU, contact events, action segments, per-frame instance masks and one task instruction per episode elsewhere. What it does not state is which of those are channels in an MCAP file, how they are named, what encoding they use or at what rate.

No topic name, message schema or rate is stated on this page, and none should be assumed. Name the streams that matter in the skill spec and confirm them on a Spec Pilot batch. The fourth table below sets each stream beside what the site states about it.

Failure modes

What goes wrong when you record bench work in stereo, and what does QA reject?

Hand occlusion by the pipette and tube is the first risk, under the visibility flag above. Weak depth on glare-heavy, wet or reflective surfaces is the second, and the behaviour on small transparent items is Not stated. Calibration is measured at the start and end of every session under a 0.28 px RMS gate, and an episode is rejected for a sync breach beyond the ceiling for more than three consecutive frames, for the manipulated object out of frame for more than 15 percent of the episode, for an undocumented bystander or for a mismatch against the named skill spec.

A reject log ships with every batch, and rejected items are recaptured at the provider’s cost. The fifth table below lists the failure modes beside what the site states.

Scale

How do off-the-shelf coverage and custom collection combine for lab work?

The October 2026 off-the-shelf catalog lists ~324,800 hours across 18 datasets, of which stereo is ~64,800 hours across 9 datasets. The site names no lab pipetting or sample handling dataset among them, so this work is custom collection, not an off-the-shelf purchase. The off-the-shelf stereo and hand-tracking video can still show the format before you write a spec.

It is custom collection at scale through a network of thousands of capture providers, for a consistent, recurring data flow to labs. Where coverage is deep, the median time from signed spec to first validated batch is a median of 48 hours; where it is thin, turnaround runs three to four weeks. The site does not say which applies to the lab environments, so the timeline is quoted against your spec. Collections are billed per validated hour, and rejected episodes and recaptures are never billed.

Ordering

How do you order a stereo lab pipetting dataset?

Describe the steps and where each starts and ends: drawing, dispensing, changing the tip, filling, capping, racking and labeling. Say whether an episode covers one transfer, one tube, one rack or a whole protocol run, what counts as the object and what counts as a finished step, the privacy rule for the space, and name the variation your pipeline is missing. Then name the streams you want in the file, the topic naming and message encoding your reader expects, whether calibration ships inside the file or beside it, and whether MCAP is the only delivery or sits beside RLDS, LeRobot or WebDataset.

Most programs begin with a Spec Pilot, a small first batch that proves the spec and accept criteria on real footage before you scale. The sixth table below shows what each spec element decides.

At a glance

What you get.

Catalog row: Pipetting
"Pipetting" (Pharmacy & Laboratory, Healthcare & Life Sciences); Medium; Available on request
Catalog row: Liquid handling
"Liquid handling" (Pharmacy & Laboratory, Healthcare & Life Sciences); Medium; Available on request
Catalog row: Lab protocols
"Lab protocols (pipetting, titration, sample handling)" (Pharmacy & Laboratory, Healthcare & Life Sciences); Hard; Available on request
Catalog rows (sample tubes)
"Fill + cap sample tubes", "Cap, vortex + rack tubes" and "Load + balance centrifuge" (Medium) and "Rack + label tubes" (Easy), all Wet Lab & Clinical Bench; Available on request
Catalog descriptions
"Draw liquid into the pipette, dispense exact volumes into tubes and change tips."; "Measure and transfer liquids between vessels with pipettes, cylinders and dispensers."; "Pipette reagents, titrate to endpoint and handle samples following the written protocol."
Catalog capture setup
Phone (head-mounted) / multiview rig on the Pharmacy & Laboratory rows; multiview rig + handheld grippers on the Wet Lab & Clinical Bench rows. The site states no stereo pair for these rows, so a stereo pair is agreed in the skill spec through the general stereo offer
Stereo head rig (06)
Dual fisheye, 1080p per eye, 62 mm baseline, per-unit calibration, 9-axis IMU, hand-tracking output; shipped as MCAP
Hand pose
21 joints per hand with a per-joint visibility flag
Sync
Hardware-triggered onto one clock; 2.0 ms cross-stream ceiling
Reagent names, volumes, pipette brands, accuracy or precision figures, cycle times, error rates
Not stated; agreed in the skill spec
GLP/GMP, biosafety, chemical safety, sterility, certification
Not stated
MCAP topics, schemas, rates
Not stated on the site; agreed in the skill spec
License
Perpetual, irrevocable, buyer-owned, non-exclusive by default

Every collection runs through the same seven-stage end-to-end custom collection pipeline. End-to-end custom data collection is a managed service that takes an AI data need from problem to owned dataset in a single accountable pipeline.

Catalog rows

Which catalog rows cover lab pipetting and sample handling, and what is their status?

Seven rows from lib/commercial-catalog-data.ts, reproduced as the catalog states them.
Task (as listed)Description (as listed)EnvironmentSkillCapture setupStatus
PipettingDraw liquid into the pipette, dispense exact volumes into tubes and change tips.Pharmacy & LaboratoryMediumPhone (head-mounted) / multiview rigAvailable on request
Liquid handlingMeasure and transfer liquids between vessels with pipettes, cylinders and dispensers.Pharmacy & LaboratoryMediumPhone (head-mounted) / multiview rigAvailable on request
Lab protocols (pipetting, titration, sample handling)Pipette reagents, titrate to endpoint and handle samples following the written protocol.Pharmacy & LaboratoryHardPhone (head-mounted) / multiview rigAvailable on request
Fill + cap sample tubesFill tubes to a mark and cap.Wet Lab & Clinical BenchMediumMultiview rig + handheld grippersAvailable on request
Cap, vortex + rack tubesCap sample tubes, vortex-mix, and rack them in order.Wet Lab & Clinical BenchMediumMultiview rig + handheld grippersAvailable on request
Rack + label tubesLabel and rack a set of tubes.Wet Lab & Clinical BenchEasyMultiview rig + handheld grippersAvailable on request
Load + balance centrifugeLoad tubes balanced in a centrifuge.Wet Lab & Clinical BenchMediumMultiview rig + handheld grippersAvailable on request

Compared pages

How does this page differ from the egocentric lab pipetting and medication pages?

Each page and what it covers. Statuses are as the site lists them; none of these pages is claimed to hold delivered hours here.
PageWhat it coversRow status as listedRelation to this page
This page: stereo lab pipetting and sample handling dataSeven rows: pipetting, liquid handling, lab protocols and four sample-tube rowsAll Available on request (Easy to Hard)Stereo pair and MCAP delivery for pipetting and sample handling
Egocentric lab pipetting and sample handling dataFourteen rows from Pharmacy & Laboratory and Wet Lab & Clinical Bench, as first-person videoAll Available on requestNot stereo as its subject; the first-person page for the same bench work, and it includes rows this page does not claim, such as weighing a reagent and titrating to an endpoint
Egocentric medication sorting and dispensing dataThree medication rows across Care Room, Nursing Home & Assisted Living and Pharmacy & LaboratoryAll three Available on requestPharmacy work with packs, charts and prescriptions; not liquid transfer at a bench
Egocentric pharmacy and lab bench dataPharmacy and lab bench rows as first-person videoAvailable on request, as the catalog lists the lab rowsBroader pharmacy and bench page; not stereo as its subject
Egocentric stereo data in MCAPThe stereo and MCAP hub across tasksNot applicableGeneral stereo and MCAP treatment; not specific to lab work

Stated vs not stated

What the site states about stereo capture for lab pipetting and sample handling

Left to right: the item, what the site states, and what that means for a lab order. “Not stated” means the site does not say.
ItemWhat the site statesFor a lab pipetting order
Catalog capture setupPhone (head-mounted) / multiview rig on the Pharmacy & Laboratory rows; multiview rig + handheld grippers on the sample-tube rowsNo stereo pair is stated for these rows; a stereo pair is a spec choice through the general stereo offer
Stereo head rig (dataset 06)Dual fisheye, 1080p per eye, 62 mm baseline, per-unit calibration, 9-axis IMU, hand-tracking output; shipped as MCAPWhether an order uses it: Not stated
Hard-environments stack4K/60 head camera, 120° lens; two 1080p/60 wrist cameras; depth 848×480 at 30 fps; 200 Hz 6-DoF IMUWhether an order uses it: Not stated
Hands, contacts and masksPer-joint visibility flag on hand pose; contact events; per-frame instance masks stored at 848×480Stated; what counts as the object is set in the spec
Hand occlusionThe hands occlude the work and fingers disappear behind objects; visibility flags and instance masks address itStated; how often it occurs on these rows is Not stated
Depth on small, shiny or transparent itemsNot statedNot claimed; raise in the spec and test on a Spec Pilot
Depth on wet or reflective surfacesDepth degrades on wet and reflective surfaces; confidence maps mask low-confidence regionsStated; behaviour on glass labware or a liquid in a vessel is Not stated
CalibrationMeasured every session and shipped with the episode; 0.28 px RMS reprojection gateStated
SynchronizationHardware-triggered onto one clock; 2.0 ms cross-stream ceilingStated
Row statusAll seven rows Available on requestNo volume, hours or delivered stereo footage is claimed on this page
Reagent names, volumes, pipette brands, accuracy or precision figuresNot statedNot claimed; set in the spec
GLP/GMP, biosafety, chemical safety, sterility, certificationNot stated; the catalog notes only that pharmacy and laboratory work requires regulatory complianceNot claimed on this page
Cycle time, error rate, task durationNot statedNot claimed on this page
Volume, liquid level, sample identity or result labelNot stated; no such label is listed for the rowsNot claimed; set in the spec
MCAP topics, schemas, ratesNot statedAgreed in the skill spec

Stream map

Streams for lab pipetting and what the site states about an MCAP file

Left to right: the stream or item, what the site states about it, and what the site states about it in MCAP. “Not stated” means the site does not say.
Stream or itemWhat the site statesIn an MCAP delivery, as the site states it
Stereo pairDual fisheye, 1080p per eye, 62 mm baseline (dataset 06)Dataset 06 is stated as shipped as MCAP; channel layout not stated
Depth with confidence mapsRecovered from the calibrated stereo pair; confidence map masks low-confidence regionsNot stated
Hand pose21 joints per hand with a per-joint visibility flagChannel layout and joint order not stated
IMU9-axis (dataset 06); 6-DoF at 200 Hz (hard-environments stack)Channel layout and rate not stated
Contact events, action segments, instance masksListed in the site episode schema; masks stored at 848×480Not stated
Task instructionOne per episodeNot stated
CalibrationMeasured every session and shipped with the episodePlacement in the file not stated
Topic names, schemas, encoding, ratesNot statedAgreed in the skill spec

Failure modes and QA

What goes wrong in bench capture, and what QA does about it

Left to right: the failure mode, what the site states, and what a buyer sees. “Not stated” means the site does not say.
Failure modeWhat the site statesWhat a buyer sees
Fingers hidden by the pipette or a tubePer-joint visibility flag on hand pose; wrist views and a multiview angle available in the specA hidden joint flagged as hidden, not guessed
Pipette tip or tube out of framePer-frame instance masks; episode rejected when the object is out of frame for more than 15 percent of itReject log per batch; what the object is gets set in the spec
Reach and grasp blur and occlusionReach and grasp frames are where blur and occlusion show up; the head camera is global-shutterHow often it occurs on these rows: Not stated
Small transparent or shiny itemsBehaviour of depth is Not statedNot claimed; raise in the spec and test on a Spec Pilot
Weak depth on wet or reflective surfacesDepth degrades on wet and reflective surfaces; confidence maps mask low-confidence regionsBehaviour on a given vessel or bench surface: Not stated
Invalid depth in the manipulation regionEpisode rejected when more than 35 percent of depth pixels are invalidReject log per batch; confidence maps ship with depth
Bystander in frameFaces and screens blurred and reviewer-confirmed; undocumented bystander rejected; footage that cannot be de-identified is discardedReject log per batch; anonymization record ships with the data
Calibration driftSolved at the start and end of every session; 0.28 px RMS gateCalibration shipped with the episode
Sync breachRejected beyond the 2.0 ms ceiling for more than three consecutive framesReject log per batch
Spec mismatchRejected for a mismatch against the named skill specReject log per batch

Skill spec

What the skill spec fixes for a stereo lab pipetting order

Spec element and where a buyer can see it in the delivery. “Set per program” means the site states no fixed value.
Spec elementWhat it decidesWhere it shows up
RowsWhich of the seven rows, worded as the catalog words themSet per program; Available on request as listed
Steps and orderWhat one step is: draw, dispense, change tip, fill, cap, vortex, rack, labelEpisode boundaries and action segments; set per program
Episode scopeOne transfer, one tube, one rack or a whole protocol runSet per program; the site does not state an episode length
Object definitionWhether the pipette tip, the tube or the cap counts as the objectContact events and the out-of-frame reject rule; set per program
Vessels and consumablesWhich of the pipettes, tubes, cylinders and dispensers the rows nameSet per program; brands and volumes are Not stated on the site
Rig and streamsStereo pair, multiview angles, wrist views, hand pose, IMU and any othersThe channels you can read; confirm on the Spec Pilot
Setting and lightingWhere capture runs and how the bench is litSet per program; the site states no lighting setup for these rows
MCAP topics and encodingWhat your reader expectsSet per program
Delivery formatHow the data is packagedMCAP alone, or beside RLDS, LeRobot, WebDataset, HDF5 or zarr
Accept criteriaWhat passes QA, including what counts as a rejectReject log per batch
PrivacyHow people, screens and labels in frame are handledFaces and screens blurred at ingest; other items agreed in the spec
LicenseWho owns the datasetPerpetual, irrevocable, buyer-owned, non-exclusive by default

Example footage

What does egocentric stereo capture look like?

One real clip already published on this site, shown as a format and rig example: a head-mounted stereo capture with hands in frame. It does not show pipetting, a lab bench, tubes or liquid handling.

egocentric_stereo_sample.mp4 · head-mounted stereo · hands in frame · 1920 × 1080 web preview · rig example, not a lab clip

No lab pipetting clip is published on the site, so this is labelled as a format and rig example. Request a sample to see delivered files. See stereo sample page, stereo + wrist-cam example videos, request an egocentric data sample.

FAQ

Lab automation robot training data, answered.

What is stereo lab pipetting and sample handling data?
First-person video from two calibrated cameras of a person pipetting, transferring liquids and handling sample tubes at a lab bench, with depth and hand pose alongside.
Which catalog rows cover it, and what is their status?
Seven, all Available on request. "Pipetting" and "Liquid handling" (Medium) and "Lab protocols (pipetting, titration, sample handling)" (Hard) are in Pharmacy & Laboratory. Four sample-tube rows are in Wet Lab & Clinical Bench. This page claims no delivered hours.
Is stereo already captured on these rows?
Not stated. The catalog lists a head-mounted phone with a multiview rig for the Pharmacy & Laboratory rows and a multiview rig with handheld grippers for the tube rows. A stereo pair is agreed in the skill spec through the general stereo offer and confirmed on a Spec Pilot.
How is this different from the egocentric lab pipetting page?
The egocentric lab pipetting and sample handling page covers fourteen bench rows as first-person video, not stereo as its subject. This page is stereo capture of pipetting, liquid handling and sample tubes, with MCAP delivery. The medication sorting page covers pharmacy work, not bench liquid transfer.
Is there an off-the-shelf lab pipetting dataset?
No listed dataset names lab pipetting or sample handling. Stereo lab data is custom collection, at scale through a network of thousands of capture providers, for a consistent, recurring data flow to labs.
Does the data include reagent names, volumes or compliance claims?
Not stated. The site lists no reagent names, volumes, pipette brands or accuracy figures, and no GLP, GMP, biosafety, chemical safety, sterility or certification claim, so none is claimed. These are set in the spec.
How does depth handle small transparent objects?
Not stated. The site states that depth degrades on wet and reflective surfaces, with confidence maps masking low-confidence regions, but gives no behaviour for small, shiny or transparent items. Raise it in the spec and test it on a Spec Pilot.
Can it be delivered as MCAP, and what is in the file?
Yes. Firsthand offers MCAP delivery. Topic names, message schemas and rates are Not stated on the site and are agreed in the skill spec.

Sources

Where is MCAP documented?

Request a custom lab pipetting dataset delivered as MCAP.

Tell us the steps and where each starts and ends, whether an episode covers one transfer, one tube, one rack or a whole protocol run, what counts as the object, the setting and lighting, the privacy rule for the space, the streams you want in the file and whether MCAP sits alone or beside a training format. We will quote reach, timeline and price against a written spec.